Mode: HCTT 50KV/100KVA
Cylinder type Cooling methods: ONAN
Rated capacity: 100KVA No-load current ≤10%
Input voltage: 0-400V Waveform deviation ≤3%
Output voltage: 350KV Dielectric loss: 0.5%
Output current: 286mA Noise level: ≤60db
Single phase Winding measuring voltage: 100V
Frequency: 50Hz Insulation level: withstand 5kV/min (Low voltage input ending to ground)
Outer dimension: φ1300mm *height2720 mm PD Measurement: ≤5pC at rated voltage, ≤2pC at 80% rated voltage
Weight: 1500KG
Transformer Oil:
25# transformer oil is from Karamay Refinery. The oil indicator can reach the oil level for 500KV transformers. Factory test of test transformer should use new transformer oil supplying with transformers and perform oil inspection before or after factory test. Oil inspection report should be provided when the transformer delivered filled with oil. Quality of transformer oil should meet the requirements of SH0040-91, GB2536-90, GB7595-87, SD187-86, Class II A of IEC-296 standards. Components PCB are prohibited in the oil. When doing acceptance test on-site, the oil performance should satisfy the following requirements: DGA analysis of total hydrocarbons less than 10 mg/L, the breakdown voltage of the oil should not be less than 65kV/2.5mm, dielectric loss (90°C) is not more than 0.3%, water content is not more than 10mg/L, the gas content is not more than 1%.
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn