HCTT-2×300kV/300kVA AC Test Transformer
Home > Systems > AC Dielectric Test > AC Test Transformer > >400kV Range

HCTT-2×300kV/300kVA AC Test Transformer

Lead time: 90 days

Mode: HCTT 2x300KV/300KVA
Cylinder type, two modules
Single phase
Frequency: 60Hz
Rated voltage: 2x300kV
Rated Output Capacitance: 300kVA
Rated Current: 0.5A
Rated feeding voltage: 0.6kV
Rated feeding current: 500A
(HV terminal of the transformer will be earthed through a current transformer 5/5 so as to check the current value of HV side and ensure safety of the operators and equipment.)
HCTT-1000kV AC Test Transformer HCTT-1000kV AC Test Transformer

HCTT-1000kV AC Test Transformer HCTT-1000kV AC Test Transformer

Waveform deviation ≤3%
Unload Current: IO<10%
Impedance voltage ≤18%
Voltage Ratio of Measurement Winding: 2000:1
Over Current Ability: Continuous working for 300S under 125% rated current, then thermal damage or distortion of the winding shall not be occurred.
Over Voltage Ability: Over voltage at 110% UH (660kV) for 60s., then it shall not happened any insulation damage for the testing transformer.
Insulation Level:10kV/1min(low voltage terminal to earth)
Noise: ≤60dB
PD Level: <10pC at 100%UH; <8pC at 80%UH
Unevenness at 2 transformer in series: ≤±5%
Operating Time: (starting from environment temperature)

Working for 60 minutes allowed at 100% rated current & voltage;
Continuous working allowed at 2/3 rated current & voltage; and temperature rise of transformer winding is less than 65K, temperature rise of oil surface is less than 55K.
Protection: The surge arrester 3kV shall be installed among excitation winding of the transformer and transfer winding for protection purpose.
Injection and release valve for transformer oil are available.

Upper Stage Transformer
Mode: HCTT-300kV/300kVA-II
Cylinder type, Single phase, Frequency: 50Hz
Rated Capacitance: 300kVA
Rated Voltage: LV Voltage: 3kV,           HV Voltage: 300kV
Rated Current: Exciting current: 100A,HV Current: 1A
Impedance Voltage ≤4%,    Waveform deviation ≤3%
Dividing Ratio of Measurement Windings:1000:1
Noise level ≤60dB (Measure in 4 meters distance)
Cooling: ONAN

Over Voltage Ability: Continuous working for 60S minutes under 110% rated voltage (330kV), then thermal damage or distortion of the winding shall not be occurred.
PD Level: <5pC at 100%UH of complete test system; <3pC at 80%UH of complete test system;

Insulation of Winding to Earth:
>2500MΩ (HV winding to LV winding to earth);
>2500MΩ (LV winding to HV winding to earth);
Insulation Level: 10kV/1min (LV winding to HV winding and transformer housing)
Insulation Level: 5kV/1min (measurement winding to LV winding, HV winding and transformer housing)
Electric Strength of Transformer Oil:
- Breakdown Voltage>60kV/2.5mm Moisture<10ppm
- Dielectric Loss<0.5%(at 90℃)
- Without acetylene in oil; Solidifying point>40

Sub-Stage Transformer
Tyoe: HCTT-300kV/600kVA-I
Single phase
Type: Insulated Barrel, fixed structure
Frequency: 50Hz
Rated Capacity: LV capacitance: 600kVA , HV Capacitance: 300kVA ,  Transfer capacitance: 300kVA
Rated Voltage: HV Volt.:300kV,           Transfer volt: 3kV
Rated Current: HV Current: 1A,  Transfer current: 100A
Impedance Voltage: ≤4%,    Waveform deviation ≤3%
Dividing Ratio of Measurement Windings:1000:1
Noise level ≤60dB (Measure in 4 meter distance)
Cooling: ONAN
PD Level: <5pC at 100%UH of complete test system; <3pC at 80%UH of complete test system;
Over Voltage: Continuous working for 60S minutes under 110% rated voltage (330kV), then thermal damage or distortion of the winding shall not be occurred.

Insulation of Winding to Earth:
>2500MΩ (HV winding to LV winding and measurement winding to earth);
>2500MΩ (LV winding to HV and measurement winding to earth);
>2500MΩ (measurement winding to HV and LV winding to earth)
Insulation Level: 10kV/1min (LV winding to HV winding and transformer housing)
Insulation Level: 5kV/1min (measurement winding to LV winding, HV winding and transformer housing)
Electric Strength of Transformer Oil:
- Breakdown Voltage>60kV/2.5mm Moisture<10ppm
- Dielectric Loss<0.5%(at 90℃)
- Without acetylene in oil; Solidifying point>40    

Principle Diagram: 
                     

  