≤100kV Range
HTTS 66KV/100KVA Tank type Test Transformer
Home > Systems > AC Dielectric Test > AC Test Transformer > ≤100kV Range

HTTS 66KV/100KVA Tank type Test Transformer

Lead time: 45days

Mode: HTTS 66KV/100KVA
Tank type                                                
Dielectric loss: <0.5%
Single phase                                          
Noise level: ≤60dB
Frequency: 50Hz  / 60Hz                                 
No-load current ≤10%
Rated Capacity: 100kVA                    
Waveform deviation ≤5%
Rated input voltage: 0.40kV  (Can be customized according to User's feeding power)                   
Measuring winding voltage: 100V
Rated output voltage: 66KV              
Cooling: ONAN
Output current: 1515mA                    
PD Level: <5pC at 100%UH of complete test system

Over-current capability: Working for 300s allowed at 120%In, not cause any damage to transformer winding and insulation.
Over-voltage capability: Working for 60s allowed at 110% rated current, not cause any damage to transformer insulation.
Insulation level: withstand 5kV/min (Low voltage input ending to ground)
Working time: working 60 min under 100% rated voltage; Continuous working allowed at 80% rated current & voltage; and temperature rise of transformer winding is less than 65K, temperature rise of oil surface is less than 55K.
Dimension: 1000mm*800mm*1650mm
Weight: 890kg

HTTS 66KV/100KVA  Tank type Test Transformer HTTS 66KV/100KVA  Tank type Test Transformer

HTTS 66KV/100KVA  Tank type Test Transformer HTTS 66KV/100KVA  Tank type Test Transformer

Transformer Oil: 
25# transformer oil is from Karamay Refinery. The oil indicator can reach the oil level for 500KV transformers. Factory test of test transformer should use new transformer oil supplying with transformers and perform oil inspection before or after factory test. Oil inspection report should be provided when the transformer delivered filled with oil. Quality of transformer oil should meet the requirements of SH0040-91, GB2536-90, GB7595-87, SD187-86, Class II A of IEC-296 standards. Components PCB are prohibited in the oil. When doing acceptance test on-site, the oil performance should satisfy the following requirements: DGA analysis of total hydrocarbons less than 10 mg/L, the breakdown voltage of the oil should not be less than 65kV/2.5mm, dielectric loss (90°C) is not more than 0.3%, water content is not more than 10mg/L, the gas content is not more than 1%.

Principle Diagram: 

  