Mode: HCR 2000KVA-10KV
1) Tank type, 50Hz
2) Rated capacity: 2000KVA
3) Rated voltage: 10KV
4) Rated current: 30~2000A
5) Linearity: <± 1%
6) Noise level: < 70db
7) Cooling: ONAN
8) Over voltage ability: withstand for 1 min under 110% rated voltage without any insulation damage to reactor winding.
9) Working time: working for 60 min under 100% rated voltage and current; temperature rising of reactor winding is ≤65K; temperature rising of oil surface is ≤55K; Copper taking current density ≤2.5A / mm2
10) Insulation level: 20KV/1 min without abnormal discharging phenomenon;
11) Structure: tank shell with adjustable iron core. On the oil tank installed measurable current transformer 250:5,and reactor conservator equipped with breather; oil drain valve on the bottom which is convenient to take oil sample.
12) Dimension: 1600mm*1300mm*2200mm
13) Weight: <5500kg