Charging apparatus is set at the bottom of generator. Output voltage is positive-negative symmetrical DC voltage. The voltage is lead by HV lead wire to Generator’s first charging resistor, supplying DC charging voltage.
Maximum charging voltage: 50kV
Charging voltage: automatic controlled, in range of 15~100%, deviation between real value and reference voltage<±1%, instability<±0.5%, adjusting accuracy: 1%
Maximum charging current: 100mA
Charging current range: 10~100mA
Oil transformer: (HV silicon rectifier stack 2DL-200kV/100mA)
Secondary voltage: 50kV
Rated capacity: 10kVA
Rated voltage: 50kV/220V
Reverse voltage of rectifier: >=200kV
Average current:>=0.1A
DC Resistance Divider: 100kV 200MΩ (2units)
Input power: 220V, 50Hz,
(Customized according to requirement, 50Hz or 60Hz are available.)
Polarity transition: remote electrical control
Adopt bilateral asymmetric charging circuit, controllable silicon constant current charging regulating. Charging voltage resolution: ≤ 1.0%
(for 100kV per stage Impulse Generators)
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn