Cylinder Type
HFRS 600kV/3000kVA Variable Frequency Resonant Reactor, Frequency Resonant Reactor
Home > Systems > Frequency Resonant > Variable Frequency Resonant Reactor > Cylinder Type

HFRS 600kV/3000kVA Variable Frequency Resonant Reactor

Lead time: 65 days

Mode: HFRS 600kV/3000kVA
Three modules
Single module rated voltage: 200kV,
Single module rated current: 5A
Single module rated capacitance: 1000kVar
Two modules rated capacitance: 2000kVar
Three modules rated capacitance: 3000kVar
Single module inductance: 100H
Two modules inductance: 200H
Three modules inductance: 300H

Insulation Level:  withstand 60s under 120% rated voltage
Rated frequency: 30-300Hz                  Quality factor: Q>60 when frequency is 60Hz
Working time: one hour one, one hour off, under rated output capacitance, not surpass 4 cycles every day. Temperature raise: winding≤80K, transformer oil≤55K; Surface of epoxy tube temperature raise ≤40K

Structure Requirement: 
The system adopts iron coil subsection air gap and copper winding structure, reactor adopts copper lead-wire winding, oil immerse self-cooling, oil tank is iron shell structure to increase the system heat dissipation capability, and equips with breathe capsule for transformer oil expanding when testing. Reactor equips reliable hook for suspending.
The inner structure of the reactor is special designed for long distance railway, highway transportation. The system suitable for on-site test.
Reactor has nameplate for single unit and serial connection: the paramter on nameplate are: Rated voltage, inductance, working frequency, weight, and so on.
Compared with Epoxy tube type structure, the Metal tank structure has better function on heat dissipation. And Tank structure has better performance on on-site testing.

Principle Diagram: 

  
  

  
Where To Buy

Related Photos

Related Researches