Mode: HFRS-T 250kV/22500kVA
Single Module                                Rated voltage: 250kV
Rated current: 90A                        Rated capacitance: 22500kVA
Rated inductance: 29.5H±2%      Insulation level: 275kV/1min; terminal: 10kV/5min
Rated frequency: 14-300Hz          Quality factor: Q>150(@15Hz)
Working time: one hour one, one hour off, under rated output capacitance, not surpass 3 cycle every day. Temperature raise: winding≤65K, transformer oil≤55K; Surface of epoxy tube temperature raise ≤40K

Structure Requirement: 
The system adopts iron coil subsection air gap and copper winding structure, reactor adopts copper lead-wire winding, oil immerse self-cooling, oil tank is iron shell structure to increase the system heat dissipation capability, and equips with breathe capsule for transformer oil expanding when testing. Reactor equips reliable hook for suspending.
The inner structure of the reactor is special designed for long distance trailway, highway transportation. The system suitable for on-site test.
Reactor has nameplate for single unit and serial connection: the parameter on nameplate are: Rated voltage, inductance, working frequency, weight, and so on.
Compared with Epoxy tube type structure, the Metal tank structure has better function on heat dissipation. And Tank structure has better performance on on-site testing.