Mode: HGTS 200KV/200KVA
Insulation cylinder, fixed type Insulation way: SF6 gas insulated
Phase: single Rated capacity: 200KVA
Frequency: 50Hz Rated voltage: LV voltage: 2*3KV HV voltage: 200KV
Rated current: LV current: 2*33.3A HV current: 1A
LV winding can be in both serial and parallel connection:
in serial connection: HV output 100KV/A; in parallel connection: HV output 200KV/A
Waveform distortion: <3%
No load current: <10%
Impedance voltage: < 12%
Over current ability: continue for 5 min under 120% rated current without any heat damage and distortion to transformer winding;
Over voltage ability: continue for 1 min under 110% rated voltage without any insulation damage to test transformer;
Sudden short circuit discharging test: discharging for 3 times to the ground by protecting resistor at 160KV output, without any damage to test transformer;
Insulation level: LV winding to ground power frequency withstand level: 10KV/1min;
HV tail to ground power frequency withstand level: 5KV/ 1min;
PD level: <5pV under 100% rated voltage; < 3pC under 80% rated voltage;
Dielectric loss: < 0.5%
Winding to ground insulation: HV winding to LV winding and ground: >1500MΩ
LV winding to HV winding and ground: >1500MΩ
Noise: ≤60dB
Working time: short circuit for 20 min under 100% rated voltage and current;
Protection: On the LV winding of test transformer mounted 3KV MOA.
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn