Mode: HVF 250KV/12500pF
Frequency: 50Hz Dielectric Loss <0.2%
Rated voltage: 250kV Measuring Accuracy: ≤±1%
Rated capacity: 12500pF Nominal Dividing Ratio: 1000:1
Insulation level: High voltage arm insulation level 275kV/1min(measuring the capacity and dielectric loss before and after raising voltage)
Low voltage arm withstand is 3kV/1min; high and low arm are made of the same medium, in order to keep the equipment divider ratio from temperature changes.
Structure: the capacitor with epoxy oil-paper insulation tube shell structure is selecting the material with small temperature coefficient.
Base should be with sufficient stability, easy to dismantle, install and equipped with casters for easy mobility.
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.