Mode: HCRS1000kV/4000kVA
Cylinder type Single phase
Frequency:50Hz Rated Capacity:4000kVA
Rated Voltage:Single module reactor voltage: 500kV, two module serial connection voltage: 1000kV
Rated Current: 4A Current adjusting range: 0.628~4A
Cooling methods: ONAN Waveform deviation ≤1.5%
Unload Current: IO<10% Impedance voltage ≤15%
Voltage Ratio of Measurement Windings:2000:1 Noise:≤70dB
Reactance adjusting range:
Technical parameter | kΩ |
Reactance (Single module) | 125~796.2 |
Reactance (Two modules serial connection) | 250~1592.4 |
Inductance adjusting range:
Technical parameter | H |
Reactance (Single module) | 398.1~2535.6 |
Reactance (Two modules serial connection) | 796.2~5071.3 |
Load capacitance:
Technical parameter | Load capacitance(pF) |
Load capacitanc of single module reactance | 25480~4000 |
Load capacitanc of two modules serial reactance | 12740~2000 |
Over Current Ability: Continuous working for 300S under 110% rated current (4.4A), then thermal damage or distortion of the winding shall not be occurred.
Over Voltage Ablity: Overvoltage at 110% UH (1100kV) for 60s, then it shall not happened any insulation damage for the testing transformer.
Quality factor: >50
PD Level:<5pC at 100%UH of complete test system, <3pC at 80%UH of complete test system.
Working time: working 60 min under 100%UH,100%IH; continuous working under 2/3UH,2/3IH; reactor winding temperature raise ≤65K, oil surface temperature rasie ≤55K, external surface temperature rasie ≤30K.
Linearity: 10%-100% reactance, error≤±1%
Structure: iron coil structure, user can change the reactance through adjusting open coil gaps, two epoxy tube, the steel bracket is made of stainless material in case of the reducing of quality factor which caused by eddy loss; pedestal has considered the heat which is caused by high-intensity magnetic field; the resonant system designation has considered the expand with heat and contract with cold of the oil.
Internal structure:
①. 30-Q-130 Grain-Oriented Electrical Steel,
②. There are earthing baffle between winding and iron coil, the earthing is reliable.
③. We do many improment on the system; abandon some unreasonable structure and creat our new resonant. New variable inductance power frequency resonant reactor’s working life not less than 60 years.
④. The iron steel has been done the chip removing treatment. And then form a entirety with curing agent, which lower the noise; equip guide rail between adjustable iron coil and fixed iron coil, to make sure the iron coil move vertical or horizontal. We have been leader of the power frequency variable resonant system, moreover, we cooperate with famous university and research institute and improve ours quality continuously.
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn