Tank Type
HTRS 100kV/1500kVA (75kV ,50kV) Inductance Resonant Reactor
Home > Systems > Inductance Resonant > Inductance Resonant Reactor > Tank Type

HTRS 100kV/1500kVA (75kV,50kV) Resonant Reactor

Lead time: 100 days

Mode: HTRS 100kV/1500kVA(75kV ,50kV)
Tank type  Single phase
Frequency: 60Hz  Indoor use
Rated voltage: 100kV, with two taps: 50kV & 75kV
Rated Capacity: 1500kVA  Current adjusting range: 15A
Cooling methods: ONAN  Waveform deviation ≤1%
Noise: ≤75dB  Quality factor: 20~100
Inductance adjusting range:

Technical parameter  Rated current Inductance Adjust Range   Load Range 
Rated voltage: 50KV   30A   4.6H ~ 95H   0.012uF~0.4uF  
Rated voltage 75kV  20A 10H ~ 200H   0.035uf~0.7uF   
Rated voltage100kV 15A   17H~587H   0.075uF~1.5uF   

Over Current Ability: Continuous working for 300S at110% rated current, then thermal damage or distortion of the winding shall not be occurred.
Over Voltage Ability: Overvoltage at 110% UH for 60s, then it shall not cause any insulation damage for the testing transformer.
PD Level :< =2pC at 100%UH of complete test system
Working time and temperature: one hour on and three hour off under rated load, everyday 6cycle.Winding temperature raise not surpass 65K, oil temperature raise less than 55K
Linearity: 10%-100% reactance, error≤±1%
Structure: iron coil structure, user can change the reactance through adjusting open coil gaps, two epoxy tube, the steel bracket is made of stainless material in case of the reducing of quality factor which caused by eddy loss; pedestal has considered the heat which is caused by high-intensity magnetic field; the resonant system designation has considered the expand with heat and contract with cold of the oil.
External structure:
① Housing is tank type, and connected with flange at two terminals, resistant to impact, low leakage current and partial discharge, external color is sky blue.
② Withstand 20kPa atmosphere sealing test, no leakage, no permanent deformation.
③ Sealing ring is acrylate material for aviations, oil resistance and thermo stability.
Transmission component structure:
①Adopt good material, use 1Ni18T9 stainless steel, which can't transmit magnet, as guide rail.
②In order to reduce the noise, adopt 1Ni18T9 stainless steel, which can't transmit magnet, double leadscrew to drag the flexible iron coil.