Mode: HTRS 120kV/2400kVA (60kV,75kV)
Tank type Single phase
Frequency: 60Hz Indoor use
Rated Capacity: 2400kVA
Current adjusting range: 10A
Cooling methods: ONAN
Waveform deviation ≤1% Noise:≤75dB
Inductance adjusting range:
Technical parameter | Rated current | Min. Inductance | Max. Inductance |
Rated voltage: 60KV | 40A | 3.98H | 79.6H |
Rated voltage 75kV | 32A | 6.22H | 124.4H |
Rated voltage120kV | 20A | 15.92H | 318.4H |
Insulation level: coupling feeding 3kV terminal to ground withstand 10kV/1min
Max. volt output terminal HV winding withstand 132kV1min.
Over Current Ability: Continuous working for 300S at110% rated current, then thermal damage or distortion of the winding shall not be occurred.
Over Voltage Ability: Overvoltage at 110% UH for 60s, then it shall not cause any insulation damage for the testing transformer.
Quality factor: >=40
PD Level : no requirement (Generally, less than 20pC)
Working time and temperature:
Tap 1: 60kV 40A; 5min on, 1min off, 30times per day
Tap 2: 75kV 32A, 5min on, 1min off, 20times per day
Tap 3: 120kV 20A, 30min on, 30min off, 10 time per day.
Winding temperature raise not surpass 65K, oil temperature raise less than 55K
Linearity: 10%-100% reactance, error≤±1%
Structure: iron coil structure, user can change the reactance through adjusting open coil gaps, two epoxy tube, the steel bracket is made of stainless material in case of the reducing of quality factor which caused by eddy loss; pedestal has considered the heat which is caused by high-intensity magnetic field; the resonant system designation has considered the expand with heat and contract with cold of the oil.
External structure:
Housing is tank type, and connected with flange at two terminals, resistant to impact, low leakage current and partial discharge, external color is sky blue.
Withstand 20kPa atmosphere sealing test, no leakage, no permanent deformation.
Sealing ring is acrylate material for aviations, oil resistance and thermo stability.
Transmission component structure:
Adopt good material, use 1Ni18T9 stainless steel, which can't transmit magnet, as guide rail.
In order to reduce the noise, adopt 1Ni18T9 stainless steel, which can't transmit magnet, double lead screw to drag the flexible iron coil.
Principle Diagram:
Related issues:
- The taps of the reactor is selected according to user's object. As such high voltage reactor can be used to test different voltage cables [or capacitor, high power products], to meet the requirement of different load and different test voltage, we normally equip several taps for reactor.
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn