Mode: HTRS 350kV/8750kVA
Related Standards:
*IEC60-1《High Voltage Test Technique》
*IEC1000《Electromagnetic Compatibility》
*GB1094《Reactor》
*GB/T1094.10-2004《Sound Glass Measurement of Transformer and Reactor》
*JB8749-1998《General Technique Requirement of Voltage Regulator》
350kV 8750kVA Inductance Resonant Reactor Layout Diagram:
Technical Parameters:
Tank type Single phase
Frequency: 50Hz Indoor use
Cooling methods: ONAN Waveform deviation ≤1%
Noise: ≤75dB (Under rated current)
Inductance adjusting range /load range table:
Rated Capacitance (kVA) 8750 /8750 Rated Voltage (kV) 350/ 250
Maximum Voltage(kV) 385 /275 Rated Current(A) 25 /25
Maximum Current (A) 27.5 /27.5
Inductance adjusting range(H) 1020‐46.1 400‐24.7
Load adjusting range (μF) 0.00995~0.22 0.0255~0.41
Operating time (min) :100% of rated voltage, 100% rated current, one hour on, three hour off; 2/3 of Rated voltage, 1/3 of rated current, continuous running 20days. Partial Discharge (pC) <2pC at rated voltage 350kV.
Temperature Raise :Oil surface temperature raise less than 55K, coil temperature raise less than 65K;
Quality Factor : Non‐load Quality factor less than 50, full load quality factor not less than 40 Over Current Ability: Continuous working for 300S under 110% rated current (27.5A), then thermal damage or distortion of the winding shall not be occurred.
Over Voltage Ability: Overvoltage at 110% UH (385kV) for 60s., then it shall not happened any insulation damage for the testing transformer.
PD Level :< 2pC at 100%UH (350kV)
Short-circuit discharge capability: HV reactor withstand 5 times discharge test at 90% of rated voltage via control over-voltage protection.
Linearity: 10%-100% reactance, error≤±1%
Structure: iron coil structure, user can change the reactance through adjusting open coil gaps, two epoxy tube, the steel bracket is made of stainless material in case of the reducing of quality factor which caused by eddy loss; pedestal has considered the heat which is caused by high-intensity magnetic field; the resonant system designation has considered the expand with heat and contract with cold of the oil.
External structure:
① Housing is tank type, and connected with flange at two terminal, resistant to impact,low leakage current and partial discharge, external color is sky blue.
② Withstand 20kPa atmosphere sealing test, no leakage, no permanent deformation.
③ Sealing ring is acrylate material for aviations, oil resistance and thermo stability.
Transmission component structure:
①Adopt good material, use 1Ni18T9 stainless steel, which can't transmit magnet, as guide rail.
②In order to reduce the noise, adopt 1Ni18T9 stainless steel, which can't transmit magnet, double lead screw to drag the flexible ciron coil.
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn