Mode: HTRS 360kVA/36kV
Tank type Single phase
Frequency:50Hz Rated Capacity: 360kVA
Rated input power: 20kVA Cooling methods: ONAN
Rated input voltage: 0.4kV Quality factor: ≥20
Rated input current: 50A Waveform deviation ≤ 0.5%
Rated output current: 12A Rated output voltage: 50kV
Rated current adjust range: 0.5A~10A
Rated load capacitance range: 44.232nF ~884.6nF
Rated impedance adjusting range: 72kΩ~3.6kΩ(Min 4.16kΩ)
PD Level:<5pC at 100%UH of complete test system
Over-current capability: Working for 180s allowed at 120%In, not cause any damage to transformer winding and insulation.
Over-voltage capability: Working for 60s allowed at 110% (40kV)rated voltage, not cause any damage to transformer insulation.
Insulation level: withstand 5kV/min (Low voltage input ending to ground)
Working time: working 60 mintues under 100% rated voltage; Continuous working is allowed at 80% rated current & voltage; and temperature rise of transformer windings is less than 65K, temperature rise of oil surface is less than 55K.
Transformer Oil:25# China made
Performance requirement:
1). Voltage continuous adjustable
2). Over-current protection
3). Gap can be adjusted smoothly, set air gap upper and lower position limited function
4). Oil level indicate, oil drain valve, priming valve
5). When no gap, the system can be use as normal test transformer, can meet the requirement of DC test.
6). Omniseal type,
7). Iron shell, movable,
Structure: iron coil structure, user can change the reactance through adjusting open coil gaps, two epoxy tube, the steel bracket is made of stainless material in case of the reducing of quality factor which caused by eddy loss; pedestal has considered the heat which is caused by high-intensity magnetic field; the resonant system designation has considered the expand with heat and contract with cold of the oil.
① Housing is tank type, and connected with flange at two terminal, resistant to impact, low leakage current and partial discharge, external color is sky blue.
② Withstand 20kPa atmosphere sealing test, no leakage, no permanent deformation.
③ Sealing ring is acrylate material for aviations, oil resistance and thermo stability.
Transmission component structure:
①Adopt good material, use 1Ni18T9 stainless steel, which can't transmit magnet, as guide rail.
②In order to reduce the noise, adopt 1Ni18T9 stainless steel, which can't transmit magnet, double lead screw to drag the flexible ciron coil.
Application:
Power Factor Correction Capacitors/ Cables/ Generators/ Bushings/ CTs, PTs and CCVTs/ Partial Discharge Testing/ C & tan delta measuring
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn