Current Limit Inductance
HIP 400KV/0.04H/50A Current Limit Inductance
Home > Systems > Inductance Resonant > Current Limit Inductance

HIP 400KV/0.04H/50A Current Limit Inductance

Lead time: 30 days

Mode: HIP 400KV/0.04H/50A
1) The function of the impedance: prevent the damage of the reactor from the object breakdown.
Prevent the high frequency noise transfer from the HV end to the object end.
2) Single phase
3) Rated frequency: 20~300Hz
4) Rated voltage: 400kV
5) Rated current: 50A
6) Rated inductance: 40mH
7)Temperature raise: continuous working under 100%IH, surface temperature raise not surpass 100K.

Principle Diagram: 

  