≥1000KV Range
HCG 2400KV-400pF Multiple Chopping Gap
Home > Systems > Impulse Generator > Multiple Chopping Gap > ≥1000KV Range

HCG 2400KV-400pF Multiple Chopping Gap

Lead time: 60 days

Mode: HCG 2400KV-400pF
1) Rated voltage:2400kV
2) Rated capacitance:400pF
3) Chopping time: 2-6us
4) Stages:3 stages
5) Chopping time different: <±0.2us
6) Quantity of sphere gap: 12pairs 
7) Gap type: 150mm diameter semi sphere gap
8) Trigger methods: Three electrodes discharge trigger
(Adopt high-performance pulse amplifier output 10kV, 100ns trigger pulse)
9) Time-delay methods: Time-delay is adjustable, electric time-delay circuit supply 250kV trigger pulse (Match up with control system, digit setting chopping time)
10) Chopped wave dispensability: Standard deviation of chopping time less than 0.1μs (as the system may need to test 550kV power transformer, the chopping voltage as IEC standard will be about 1.1time of 1675kV (L.I), so the voltage close to 1800kV. And chopping normally done at 80% of voltage, so the chopping device will need about 2400kV.)

HCG 2400KV-400pF Multiple Chopping Gap, Impulse Voltage Generator HCG 2400KV-400pF Multiple Chopping Gap, Impulse Voltage Generator

HCG 2400KV-400pF Multiple Chopping Gap, Impulse Voltage Generator HCG 2400KV-400pF Multiple Chopping Gap, Impulse Voltage Generator

Principle Diagram: 

Where To Buy

Related Researches