Mode: HCG 2400KV-400pF
1) Rated voltage:2400kV
2) Rated capacitance:400pF
3) Chopping time: 2-6us
4) Stages:3 stages
5) Chopping time different: <±0.2us
6) Quantity of sphere gap: 12pairs
7) Gap type: 150mm diameter semi sphere gap
8) Trigger methods: Three electrodes discharge trigger
(Adopt high-performance pulse amplifier output 10kV, 100ns trigger pulse)
9) Time-delay methods: Time-delay is adjustable, electric time-delay circuit supply 250kV trigger pulse (Match up with control system, digit setting chopping time)
10) Chopped wave dispensability: Standard deviation of chopping time less than 0.1μs (as the system may need to test 550kV power transformer, the chopping voltage as IEC standard will be about 1.1time of 1675kV (L.I), so the voltage close to 1800kV. And chopping normally done at 80% of voltage, so the chopping device will need about 2400kV.)
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn