<1000KV Range
HCG 300KV-400pF Multiple Chopping Gap, Impulse Voltage Generator
Home > Systems > Impulse Generator > Multiple Chopping Gap > <1000KV Range

HCG 300KV-400pF Multiple Chopping Gap

Lead time: 45 days

Mode: HCG 300KV-400pF
1) Rated voltage: 300kV
2) Rated capacitance: 400pF
3) Stages: 1 stage
4) Quantity of sphere gap:  4 pairs
5) Gap type: 150mm diameter semi sphere gap
6) Trigger methods:Three electrodes discharge trigger
(Adopt high-performance pulse amplifier output 10kV, 100ns trigger pulse)
7) Time-delay methods:Time-delay is adjustable, electric time delay circuit supply 250kV trigger pulse (Match up with control system, digit
setting chopping time)
8) Chopped wave dispensability: Standard deviation of chopping time less than 0.1μs

Principle Diagram:     

Where To Buy

Related Researches